Environmental reporting according to affaldsforbrændingsbekendtgørelsen

Reporting according to the executive order on incineration plants that incinerate waste? ReportLoq is the obvious choice for you.
Here you will find all the required reports, support for EN 14181, the QAL system, 60 hour accounting and much more.
ReportLoq has support for BEK no. 1271 of 21/11/2017.

ReportLoq has all the reports that need to be used when you have to follow the executive order for plants that incinerate waste. The reports can be downloaded as PDF and Excel files and together form the overview you need. In the cloud-based versions of ReportLoq, you can even have them emailed to you, so you do not have to log in every day to download them.

Waste reporting reports include:

  • Interval – Aggregate validated measurements on an hourly, daily and monthly basis. Provides an overview of the operation with quick identification of exceeded intervals

  • Green values – The report can be used as input for tax reporting and contains STA and LTA without deducting the confidence interval and with replacement of invalid values with the highest valid STA value one week back according to BEK. No. 723 of 24/06/2011 $3

  • Tax – The report can be used for tax payment and contains calculation of derived kilograms for day / month / year

  • Overruns, A-column – The A-column report is a detailed inventory of many types of overruns and underruns for day / month / year

  • Overruns, B-column (97%) – The B-column report must document that 97% of the range values are below the stated limit value for the B-column at annual level

  • Overruns, comment – The report is a detailed view of overruns and comments grouped by date, cause and action

  • Exceedance, immediate reporting – In the case where selected violations must be reported to the authorities within a short time frame, the immediate report is used

  • QAL Values – The report shows created QAL2 and QAL3 values grouped on the measured component

  • QAL2 valid calibration interval – Weekly inventory of intervals measured outside the meter’s valid calibration interval according to EN 14181: 2014 (E) 6.5

  • Cutting – If you have high CO peaks measured on a bus, ReportLoq can cut these. The report serves as documentation for compliance with EN17255-1 Annex C

Fully integrated QAL function

CUSUM calculations according to EN14181

It does not get any easier

Emission monitoring

Keep an eye on your emissions and avoid environmental overruns.

ReportLoq’s easy-to-understand user interface gives you a quick overview of whether you are exceeding your limit values, by color-coding possible exceedances before they have occurred. The function allows the operators in the control room to quickly see if something is wrong, so they do not have to spend precious time reading all measured values.

Exceedances and alarms are clearly visible and can be forwarded to the control system as summation alarms.

See the options

ReportLoq is available in four versions, where ReportLoq + and ReportLoq + Cloud are particularly suitable.

  • ReportLoq + Cloud is the best-selling solution for waste reporting

  • ReportLoq + works without internet but is with full functionality